Premicath

Product code: 1261.153G

Peripherally inserted polyurethane catheter (radiopaque) for parenteral nutrition and administration of medication in very low weight premature babies and in neonates.Premicath codes 1261.20G and 1261.203G are inserted with a splitting needle, totally removed after catheter placement.Premicath codes 1261.153G and 1261.207G are inserted with a 24G short IV cannula.Premicath code 1261.205 is inserted with a split short IV cannula (Neocath Split) which is totally removed after catheter placement.Premicath code 1261.208G is inserted with a peelable cannula (Microflash) which is totally removed after catheter placement.Premicath code 1261.306G is supplied without introducer. The practitioner can thus choose the introducer that fits him best: standard short IV cannula, split short IV cannula, splitting needle, peelable cannula...
Premicath is presented in a rigid tray containing:- 1 PU catheter (XRO) Ø 0,17 mm x 0,35 mm with fixation wings or with pink connector to fix the non removable 24G I.V. cannula. The catheter has an integral polyurethane extension tube (8 cm long, Ø 0,5 x 1,6 mm) with clamp and features markings every centimetre.- 1 introducer which is either a splitting needle (Ø 0,7 mm, 19 mm long), or a 24G short I.V. cannula (Ø 0,7 mm, 19 mm long), or a split I.V. cannula (Neocath Split Ø 0,9 mm - 20 mm long) or a peelable cannula (Microflash Ø 1,0 mm - 21 mm long).
Some versions of Premicath are supplied without introducer (see codes here-above).- 1 measuring tape to measure the length of catheter to be inserted from the puncture site to the junction superior vena cava / right atrium.- Some models of Premicath are supplied with a stylet (see table of technical characteristics). The stylet is supplied with a Y connector. A syringe filled with saline solution can be connected to the lateral port of the Y connector to prime the catheter or to lubricate the stylet in case of difficulty when removing the stylet or to infuse a solution in case of venous spasm. 


  Code Catheter Ø
Fr
Catheter Ext. Ø
mm
Catheter Length
cm
Catheter Gauge
G
Catheter Flow rate for 1 bar pressure
ml/min
Catheter Prim. vol.
ml
Introducer Length
mm
Introducer Ext. Ø
mm
Introducer G
G
Introducer - Stylet -
1261.153G 1 0.35 15 - 0.9 0.08 19 0.7 24 Cannula Yes
1261.203G 1 0.35 20 28 0.7 0.09 19 0.7 24 Breakaway needle Yes
1261.205G 1 0.35 20 28 0.7 0.09 20 0.9 22 Neocath Split Yes
1261.207G 1 0.35 20 28 0.7 0.09 19 0.7 24 Short IV canula Yes
1261.208G 1 0.35 20 28 0.7 0.09 21 1.1 20 Microflash Yes
1261.20G 1 0.35 20 28 - 0.09 19 0.7 24 Breakaway needle No
1261.306G 1 0.35 30 - 0.6 0.11 - - - - -
  Catheter Introducer Stylet
Code Ø
Fr
Ext. Ø
mm
Length
cm
Gauge
G
Flow rate for 1 bar pressure
ml/min
Prim. vol.
ml
Length
mm
Ext. Ø
mm
G
G
- -
1261.153G 1 0.35 15 - 0.9 0.08 19 0.7 24 Cannula Yes
1261.203G 1 0.35 20 28 0.7 0.09 19 0.7 24 Breakaway needle Yes
1261.205G 1 0.35 20 28 0.7 0.09 20 0.9 22 Neocath Split Yes
1261.207G 1 0.35 20 28 0.7 0.09 19 0.7 24 Short IV canula Yes
1261.208G 1 0.35 20 28 0.7 0.09 21 1.1 20 Microflash Yes
1261.20G 1 0.35 20 28 - 0.09 19 0.7 24 Breakaway needle No
1261.306G 1 0.35 30 - 0.6 0.11 - - - - -
  • Contains Latex: No
  • Contains DEHP: No
  • Contains products of animal or biological origin: No
  • Pyrogen-free: Yes